Reviews (3)

Mar 12, 2024
Cleared 005 error code
Item was as described. This is a better version than the OEM and I hope it will last longer. My Midmark M11-002 sterilizer threw a 005 error which points to stuck solenoids (vent or fill), Vent bellows or a needed re-calibration. I cleaned the solenoids but it still threw a 005 code. Replacing the vent bellows cleared the error.

Nov 01, 2025
Good printer but needed work before use.
Good printer but it needed to be glued back together before use. When I received the printer with all the necessary cables, I noticed one side of the part of the printer that clamps onto the roll of labels was not completely assembled. After collecting the 2 pieces that needed to be attached together, I realized it needed to be assembled with superglue as there seemed to be nob way to reassemble them together with any clips. The superglue worked well. After waiting overnight, I was able to install the printer to a computer. Printout is very good.

Jun 01, 2017
Replacing the RV faucet
This is a great replacement for the plastic faucet originally installed on the RV. It was a direct drop-in replacement. The female coupling that attaches to the one way valve is very shallow and I was concerned about being able to screw it onto the valve with few threads but with careful wrenching, the female coupling did screw onto the valve without leaking. I have let this plumbing maintain pressure for over 1 week and have not experienced any leaking!! Great value!! The bad: No instructions are included but here is a hint: The faucet is "off" when the handle points in the same direction as the spigot. Turning the handle towards the ceiling of the spigot is initially cold water. Continued turning of the handle pointing handle to the rear of spigot is hot water. Plumb your hot and cold water lines accordingly.