The "2018 International Building Code, Loose-Leaf Version" by International Code Council is a textbook in ringbound format published in 2017. It focuses on subjects related to Technology & Engineering, Education, Construction, Technical & Manufacturing Industries & Trades, and Teaching Methods & Materials. The book is written in English and weighs 94.6 ounces. It is a valuable resource for those studying or working in the fields of construction, engineering, and education, providing comprehensive information on building codes and regulations.
Oops! Looks like we're having trouble connecting to our server.
Refresh your browser window to try again.
About this product
Product Identifiers
PublisherInternational CODE Council
ISBN-101609837347
ISBN-139781609837341
eBay Product ID (ePID)239649322
Product Key Features
Publication Year2017
SubjectConstruction / General, Technical & Manufacturing Industries & Trades, Teaching Methods & Materials / Arts & Humanities
Publication Name2018 International Building Code, Loose-Leaf Version
LanguageEnglish
TypeTextbook
Subject AreaTechnology & Engineering, Education
AuthorInternational Code Council
FormatRingbound
Dimensions
Item Weight94.6 Oz
Additional Product Features
Table Of Content1. Scope and Administration. 2. Definitions. 3. Occupancy Classification and Use. 4. Special Detailed Requirements Based on Use and Occupancy. 5. General Building Heights and Areas. 6. Types of Construction. 7. Fire and Smoke Protection Features. 8. Interior Finishes. 9. Fire Protection Systems and Life Safety Systems. 10. Means of Egress. 11. Accessibility. 12. Interior Environment. 13. Energy Efficiency. 14. Exterior Walls. 15. Roof Assemblies and Rooftop Structures. 16. Structural Design. 17. Special Inspections and Tests. 18. Soils and Foundations. 19. Concrete. 20. Aluminum. 21. Masonry. 22. Steel. 23. Wood. 24. Glass and Glazing. 25. Gypsum Board, Gypsum Panel Products and Plaster. 26. Plastic. 27. Electrical. 28. Mechanical Systems. 29. Plumbing Systems. 30. Elevators and Conveying Systems. 31. Special Construction. 32. Encroachments into the Public Right-of-Way. 33. Safeguards During Construction. 34. Reserved. 35. Referenced Standards. 36. Appendix A: Employee Qualifications. 37. Appendix B: Board of Appeals. 38. Appendix C: Group UA. 39. Appendix D: Fire Districts. 40. Appendix E: Supplementary Accessibility Requirements. 41. Appendix F: Rodent Proofing. 42. Appendix G: Flood-Resistant Construction. 43. Appendix H: Signs. 44. Appendix I: Patio Covers. 45. Appendix J: Grading. 46. Appendix K: Administrative Provisions. 47. Appendix L: Earthquake Recording Instrumentation. 48. Appendix N: Replicable Buildings.
SynopsisThis code applies to all buildings except detached one- and two-family dwellings and townhouses up to three stories. The 2018 IBC contains many important changes such as: Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory. New code sections have been introduced addressing medical gas systems and higher education laboratories. Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction based on allowable building area and height. Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to address smoke intrusion into the hoistway. The occupant load factor for business uses has been revised to one occupant per 150 square feet. Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served. The minimum lateral load that fire walls are required to resist is five pounds per square foot. Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again with ultimate design wind speeds now called basic design wind speeds. Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values). Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed. New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven fasteners for the 20-penny nail. Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.
Three-ring binding is a good format for the IBC generally. I do wish the binder was a smaller size to better sit or stand with parallel front and back covers. If you set another book on top of this binder, it will slip down the slope created by the overly large spine/rings.
Text is clear, graphics are crisp and its obviously not a cheap unauthorized ripoff. That said, the paper is a little too thin in my estimation. A new hi-lighter that is quite wet will bleed through to the other side of the page.