Emerson White-Rodgers 50A55-843 Universal Integrated Furnace Fan Control Board

US $99.00
or Best Offer
or 4 interest-free payments of $24.75 available with
Condition:
New – Open box
‎This item is new old stock (NOS) and open box. It has never been installed or used. The original ... Read moreabout condition
Pickup:
Shipping:
US $9.89 USPS Ground Advantage®.
Located in: Leonard, Michigan, United States
Delivery:
Estimated between Thu, Sep 25 and Wed, Oct 1 to 94104
Estimated delivery dates - opens in a new window or tab include seller's handling time, origin ZIP Code, destination ZIP Code and time of acceptance and will depend on shipping service selected and receipt of cleared paymentcleared payment - opens in a new window or tab. Delivery times may vary, especially during peak periods.
Returns:
Seller does not accept returns.
Payments:
       .
Earn up to 5x points when you use your eBay Mastercard®. Learn moreabout earning points with eBay Mastercard

Shop with confidence

eBay Money Back Guarantee
Get the item you ordered or your money back. Learn moreeBay Money Back Guarantee - opens new window or tab
Seller assumes all responsibility for this listing.
eBay item number:146379156200
Last updated on Apr 17, 2025 10:29:04 PDTView all revisionsView all revisions

Item specifics

Condition
New – Open box
An item in excellent, new condition with no functional defects. The item may be missing original packaging and may have been used for testing or demo purposes. The item includes accessories found with the original product and may include a warranty. See the seller's listing for full details and description. See all condition definitionsopens in a new window or tab
Seller Notes
“‎This item is new old stock (NOS) and open box. It has never been installed or used. The original ...
Compatible Brand
For Amana, For Carrier, For Goodman, For Honeywell, For ICP, For Trane, For Universal, For YORK, For White-Rodgers, For American Standard
Power Source
Corded Electric, Gas, NG (Natural Gas)
Compatible Model
50A55-843, 5001-7744B, 156-5432C
MPN
50A55843
Material
Silicone, Silicon Carbide, Plastic
Item Length
8 in
Compatible Product
Central Furnace, Central Air Conditioner
Power Phase
1 Phase
Brand
White-Rodgers
Type
Furnace Control Board
Voltage
120 V
Model
50A55-843
Item Width
4 in
Item Weight
12.8 ounces
UPC
0786710100437
Category

Item description from the seller

About this seller

Estate Sale Secrets

96.8% positive feedback870 items sold

Joined Mar 2003
Welcome to Estate Sale Secrets, your go-to destination for discovering unique treasures with a rich history. I'm passionate about finding and curating a diverse array of vintage items, each with its ...
See more

Detailed seller ratings

Average for the last 12 months
Accurate description
4.8
Reasonable shipping cost
4.7
Shipping speed
5.0
Communication
4.9

Seller feedback (196)

All ratings
Positive
Neutral
Negative
  • c***u (214)- Feedback left by buyer.
    Past 6 months
    Verified purchase
    Great seller! Excellent communication, fast shipping with careful packaging, and item exactly as described. Thank you!
  • s***5 (33)- Feedback left by buyer.
    Past 6 months
    Verified purchase
    Shipped quickly and in protective packaging. Seller followed up to ensure delivery. The handles themselves are beautiful and as described. Great value for the price!
  • a***h (10850)- Feedback left by buyer.
    Past 6 months
    Verified purchase
    Quickly shipped. As described, very fragrant, should give a nice boost to my garden! Helpful and professional seller. Highly recommend.

Product ratings and reviews

4.7
30 product ratings
  • 26 users rated this 5 out of 5 stars
  • 2 users rated this 4 out of 5 stars
  • 0 users rated this 3 out of 5 stars
  • 1 users rated this 2 out of 5 stars
  • 1 users rated this 1 out of 5 stars

Good value

Would recommend

Good quality

Most relevant reviews

  • Top favorable review

    Replacement for 50A50-571 for Trane applications

    I have two Trane XE1200 air conditioning units circa 1998 installed originally with the 50A50-571 control boards. One of the control boards became defective during 2008 winter and furnace would not start on call for heat. The second one went bad after few years this 2019 spring when call for cooling did not fire up the circulator fan. I found this one was replacement for the discontinued board. It is smaller size than the original board and connectors have been moved around. The manufacturer has provided few jumper cables to extend original wiring in case they are out of reach due to change in position. I had to use these cables as the original would not reach the new positions. For Trane application, one has to also use the supplied jumper cable to connect the terminals for the roll out ...

    Verified purchase: YesCondition: NewSold by: patriot-supply

  • Critical item for your comfort, easy to replace.

    This Furnace control unit was used on many older a/c-furnaces and based on my experience, they last around 10 years, so the cost per year is pretty reasonable. This is my third one (been here since 1992) and while it 's annoying to have your furnace or a/c go out (just when you need it) knowing it's a weak spot and can be fixed easily makes me feel a little better. As for a DIY project, it's a good idea to take photos of the wire placements so if you lose track during the replacement, you can go back to the photo.

    Verified purchase: YesCondition: NewSold by: zorotools

  • Heating problem solved, easy installed

    Replaced my white rodgers 50A50-241 with 50A55-843 with no problems it was exact wire plugs. Had to drill four new holes for new Module but that was it. My old module would make my blower run by itself with everything on the off position and heater will run only for a short time then cut off and blower would continue on had to turn off at the breaker. Very satisfied with product would recomend.

    Verified purchase: YesCondition: NewSold by: patriot-supply

  • Quick Fix

    My control board led wasn’t blinking even though it had power. I bought this and installed it by moving one wire at a time. When I was done, I turned on the power and the furnace lit instantly. This was an exact match and the job couldn’t have been easier. Highly recommended.

    Verified purchase: YesCondition: NewSold by: supplystuf

  • Replace it with the Universal Control Module

    Instruction is easy to follow for installation and setting up the dip switch. You need to mount the module to a difference location if you are not going to use the jumper leads that come with it. Ran fine (I'm in HVAC field for a living).

    Verified purchase: YesCondition: Pre-OwnedSold by: fairguy100