Current slide {CURRENT_SLIDE} of {TOTAL_SLIDES}- Best Selling in Other Sensors
Current slide {CURRENT_SLIDE} of {TOTAL_SLIDES}- Save on Other Sensors
the wires inside were not soildered on very well, by the quick disconnect and were touching the other wire, i had to re soilder, for that one less star, overall, not bad, thanks.
Verified purchase: Yes | Condition: New
Compared to other rtd probes I've calibrated transmitters with, these have a very slow response time. The thin film element inside is loose inside the outer sheath. Therefore it ends up measuring the air space inside more instead of the process environment against it. Not good for processes that require temp control. Best used as a reference only probe.