additional items. Affinity R-410A Split System Air Conditioner 18 SEER Model # CZE03811 DESCRIPTION: 2 SPEED The CZE Series condensing unit is the outdoor part of a versatile air conditioning system. It is designed to be custom matched with one of our complete line of evaporator sections, each designed to serve a specific function. Matching air handlers are available for upflow, downflow, and horizontal left or right application to provide a complete system. Electric heaters are available if required. Add-on coils are available for use with upflow, downflow, or horizontal fumaces. Field installed accessories are available as needed. FEATURES Superior Coil Protection - A stampeddecorativemetalcoil guard completely protects coil from debris and other large damaging material while a polymer mesh further protects the coil against smaller particles. Color Grilles -Engineered around the needs and wants of the consumer, Affinity units are now available with a choice of color options designed to compliment any home. Isolated Compressor Compartment- A moldedcomposite bulkhead isolates the compressor from the rest of the unit reducing sound and vibration. Protected Compressors - Each compressoris protected against abnormal pressures by an internal pressure relief valve and factory installed high and low pressure controls. Environmentally Friendly Refrigerant - Next generation refrigerant R-410A delivers environmentally friendly performance with zero ozone depletion. Durable Finish - Automotive quality finish provides the ultimate protection from harmful U.V. rays and rust creep ensuring long-lasting high quality appearance. A powder-paint topcoat is applied over a baked-on primer, using a galvanized, zinc coated steel base material. The result is a finish that has been proven in testing to provide 33% greater durability than conventional powder-coat finishes. Lower Installed Cost - Designed to provide enhanced installability by featuring a slide-down control compartment and angled service valves to reduce overall installation time and cost. Low Operating Sound Levels - A fan design boasting technology adapted from aeronautic and defense engineering provides for whisper quiet operation by allowing airflow to flow smoothly and efficiently across the fan tips. Filter-Drier - A factory installed, solid core liquid line filterdrier filters harmful debris and moisture from the system. Easy Service Access - A full end, full service, access panel with handle makes for easy entry to internal components. Composite Base -Strongand durablecompositebasepan resists rust and corrosion while it helps reduce vibrations and noise. Quiet drive system -The swept-wing fan, composite base pan, isolated compressor compartment, electronically controlled fan motor and two-stage compressor are engineered as a system to reduce overall sound to a mere whisper. Low RPM fan motor -Helps to reduce airflow noise. Physical and Electrical Data 1 Rated in accordance with ARI Standard 110, utilization range "A". 2 Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3 Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4 The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. .Expander fitting required for 1-1/8" line set. MODEL CZE06011 UnitSupplyVoltage - 208-230V, 1, 60Hz Normal Voltage Range - 187 to 252 Minimum Circuit Ampacity - 23.6 Max. Overcurrent Device Amps -40 Min. Overcurrent Device Amps - 25 Compressor Type -Scroll Compressor Amps Rated Load 16.7 Locked Rotor - 82 Crankcase Heater - No Fan MotorAmps - Rated Load 2 Fan Diameter Inches - 22 FAN MOTOR: Rated HP- 1/3 NominalRPM - 685 NominalCFM - 2500 COIL FaceArea Sq.Ft.- 20.58 Coil Rows Deep - 2 Fins/Inch 22 LiquidLine Set00 (FieldInstalled) 3/8 VaporLineSet 0D (Field Installed) 7/8 Unit Charge (Lbs. - Oz.) 11 - 4 Charge Per Foot, Oz. 0.67 OperatingWeight Lbs. 260 Unit Dimensions: Length - 37 Width - 31 Height - 39 1/2 If there are ever any problems we will do whatever it takes to make the buyer happy. We do what is necessary to avoid negative feedback for both us and the buyer. Contact us with any questions or concerns that you may have. Thank you. Arkansas and Missouri residents must pay sales tax. Shipping Quotes are rated for commercial w/loading dock addresses. If a lift gate truck is needed, additional charges will apply. You can email us @ sales@wades.me Our business hours are M-F 8am-4pm.
HVAC TERMS Upflow Furnace - A furnace that pulls in air from the bottom and releases it
through the top. Downflow Furnace - A furnace with an intake on the top and an air discharge at the
bottom. Horizontal - A furnace that lies on its side, pulling air from one side
and pusing air out the other. Fan Coil - Indoor section of a split system heat pump or a/c
that includes fan-blower, and evaporator coil Air Handler - Parts of a system including the fan-blower, filter and
housing. Condenser - Outdoor section of a split system air conditioner. Heat Pump - A device used for either the heating or cooling of a space by
transferring heat between two reservoirs. Evaporator Coil - A device that is designed to absorb heat in the air in order to
change the liquid refrigerant that flows through it into a vapor. Package Unit - A heating and cooling system contained in one outdoor unit. SEER - Seasonal Energy Efficiency Ratio: A rating system developed by the
U.S. Government to indicate the efficiency level of cooling equipment. CFM - Cubic
Feet per Minute. A measurement of airflow volume BTU - British Thermal Unit measures the amount of heat required to raise
or lower the temperature of one pound of water one degree Fahrenheit. AFUE - Annual Fuel Utilization Efficiency: A measurement used to rate
furnace efficiencies by dividing the ratio of heat output by heat input |